Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Trinidad and Tobago INCINERATOR.Q&A

Question: Brick and refractories to withstand 1700°C (3092°F)

Our std. high density castable refractory material is rated for 3000°F (1649°C).  There is 3100°F material available but is considerably more expensive and labour intensive to work with. The point is why?  The incinerator will never exceed 2200°F (actually 2000°F), so what is the value? 

 

TRHA Response: We have experienced temperature spikes in the past due primarily to lack of waste management at the various patient-care facilities and wish to have a machine that can handle flammables, aerosols etc.

 

Question: Surface temperature of the external wall shall not exceed 80°C (176°F). 

This would most likely require dual casing.  However, they do not specify what normal operating combustion chamber temperature must be. 

 

TRHA ResponseCurrent operating temperatures are rated at 1000°C in the primary chamber and 1500°C in the secondary chamber.

 

Question: “The burner configuration shall be designed to burn a minimum of 150 kg waste per cycle cycle.” What is to be considered a cycle, per hour, per day, ??? (assume this to mean per hour).

 

TRHA Response: A cycle is how much time the machine would take under normal operating conditions to destroy 150kg of waste. This time is to be specified by the supplier.

Question: How many hours per day will the system be operated? 

TRHA Response: The plan is to run for a minimum 16 hours with an 8 hour cool-down period.

 

Question Wet scrubber: 

What performance specifications are to be met? It appears all they are suggesting is an acid gas scrubber.  

TRHA Response: Acid-gas and ceramic scrubbers appear to be standard.

 

Questions Emissions monitoring:  What emissions parameters are to be monitored? 

Response parameters:

Testing Parameters  – Stack Emission

Particulate Matter

Volatile Organic Compounds

Sulfur Dioxide (SO2)

Dioxins and Furans

Oxides of Nitrogen (NOx)

Lead (Pb) and its compounds

Ozone

Antimony (Sb) and its compounds

 Carbon Monoxide (CO)

Arsenic (As) and its compound

Fluorine (F) and its compounds

Cadmium (Cd) and its compounds

Acids and acid gases such as hydrogen chloride (HCl)

Mercury (Hg) and its compounds

Chlorine (Cl) and its compounds

Heavy Metals (other)

 

Hydrogen Sulphide

 

For the ambient air quality testing, the following parameters shall be measured:

Testing Parameters – Ambient Air Quality

Carbon Monoxide (CO)

Sulfur Dioxide (SO2)

PM10

Nitrogen Dioxide (NO2)

PM2.5

Ozone

 

Question: Incinerator operation designed with the least of zero human intervention with the waste?  Is a normal ram loader considered to meet this intent? 

 

TRHA Response- This option will be considered. All options submitted would be considered and evaluated on a case-by-case basis.

 

Question “All metals used on construction of the incinerator and its attachments must be Stainless Steel 316 grade”

It can be done but would increase the cost of the system exponentially.  

TRHA Response- Boiler quality material or some combination thereof will be considered on a case-by-case basis

 

Question 480V, 3 ph, 60Hz??  (This would be great, but do they have this power actually available?) 

TRHA Response: As discussed during the site visit, the TRHA will provide this power to a panel at the site. The contractor is responsible for connections between this panel and the machine.

 


Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com&nbsp

Incinerator Items/Model

HICLOVER TS200

 

Burn Rate (Average)

150-200 kg/hour

Feed Capacity(Average)

200kg/feeding

Control Mode

PLC Automatic

Primary Combustion Chamber

1500Liters(1.5m3)

Internal Dimensions

1500x1000x1000mm

Secondary Chamber

750Liters(0.75m3)

Smoke Filter Chamber

Wet Scrubber

Feed Mode

Manual/Auto.

Voltage

380V

Power

10.0Kw

Burner Type

Italy Brand

Oil Consumption (kg/hour)

23

N.Gas Consumption (m3n/hour)

***

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic Protection Operator(APO)

Yes

System Testing Model

Yes

Time Setting

Yes

Progress Display Bar

LCD Display

Oil Tank

200L

Oil Tank Stand

Yes

Liquid level Display

Yes

Feeding Door

800x600mm

Feeding Door Location

 

Default: Top Feeding Door

Optional: Front/Side Feeding Door, Wet scrubber

Chimney

10Meter

Chimney Type

Stainless Steel 304

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

12000kg(12.0Ton)

External Dimensions

6000x1600x2500mm(without chimney/water tank)

1st. Chamber Composition Hot Face

High alumina refractory brick Thickness: ≥115 mm

Composition 55% of Al203

1750°C Grade

2nd. Chamber Composition Hot Face

High alumina refractory brick Thickness: ≥115 mm

Composition 75% of Al203

1790°C Grade

Chamber Cold Face Material

High Rate Refractory Ceramic Fiber

Other Parts Hot Face Refractory

Heavy Duty with steel fiber

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

yes

Top Loading Door

yes

Paint for outside face

250°C Grade

Sealing Material

Refractory Ceramic Fiber

Upgrade Containerized Mobile Type

none

CE Certificate

CE(2006/42/EC,2014/30/EU

ISO Certificate

 ISO9001:2015

High-tech Enterprise Certificate

Yes

What are the objectives of incineration?

What are the objectives of incineration?
Incineration plants produce heat and power from waste, reduce waste disposal to landfills, and discharge 
harmful emissions and bottom ash. The objective of the incineration plant is to maximize desirable outputs 
(heat and power) and minimize undesirable outputs (emissions and bottom ash).
 
What is incinerators used in hospitals?
Medical incinerators are designed safely to dispose of harmful materials at high temperatures. The process 
ensures no harmful gases are released into the environment. Medical waste incinerators have scrubbers to 
clean the polluted gases and other particulate matter.
Which is better landfill or incineration?
Its director Jacob Hayler told us: “It is better to recover energy from non-recyclable waste through (incineration), than send it to landfill.” … Mr Hayler says that overall greenhouse 
gas emissions from incineration are lower than from landfill.
How does incineration affect our environment?
Pollutants emitted by incinerators that appear to have the potential to cause the largest health effects are 
particulate matter, lead, mercury, and dioxins and furans. However, there is wide variation in the contributions 
that incinerators can make to environmental concentrations of those contaminants.


 

 

 
Nanjing Clover Medical Technology Co.,Ltd.
temperature required for body parts incineration
incinerator for clinical
methods of waste management
haat incinerator india
contact number for hazardous waste management companies in kumasi
https www pvc org en p pvc incineration dioxins
disposal of clinical waste
Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be 
installed/retrofitted with the incinerator to achieve emission limits.”
“Each unit shall include a complete vertical exhaust and stack system, including the following features:
• Steel construction.
• Refractory lining in the lower section.
• The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending on 
the capacity of the incinerator unit. 
• The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not less 
than 10 metres per second vertically upwards when at full scale operation.
• An emission stack sampling port shall be included immediately above the secondary chamber.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

4.5.2 If the Contractor is not the original manufacturer of the goods, the Contractor shall provide UNOPS with the benefit of 
all manufacturers’ warranties in addition to any other warranties required to be provided under the Contract;
4.5.3 The goods are of the quality, quantity and description required by the Contract, including when subjected to conditions 
prevailing in the place of final destination;
The goods are free from any right of claim by any third-party, including claims of infringement of any 4.5.4intellectual property
 rights, including, but not limited to, patents, copyright and trade secrets;
4.5.5 The goods are new and unused;
4.5.6 All warranties will remain fully valid following any delivery of the goods and for a period of not less than one (1) year following 
acceptance of the goods by UNOPS in accordance with the Contract;
4.5.7 During any period in which the Contractor’s warranties are effective, upon notice by UNOPS that the goods do not conform to 
he requirements of the Contract, the Contractor shall promptly and at its own expense correct such non-conformities or, in case of its inability to do so, replace the defective goods with goods of the same or better quality or, at its own 
cost, remove the defective goods and fully reimburse UNOPS for the purchase price paid for the defective goods; and,
4.5.8 The Contractor shall remain responsive to the needs of UNOPS for any services that may be required in connection 
with any of the Contractor’s warranties under the Contract.

 

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 
Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com 
Email:     sales@hiclover.com       
Email:    hicloversales@gmail.com    

MEDICAL WASTE INCINERATOR


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.
1. Incinerator 10kg per hr
2. Incinerator 20kg per hr
3. Incinerator 50kg per hr
4. Incinerator 100kg per hr
5. INDOOR INCINERATOR

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

medical waste disposal methods


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

PORT SUDAN


 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices and be protected by steel conduits, cable trays, and supports.
The manufacturer should permanently mark on the incinerator indicating: (i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture of the incinerator (iii) capacity in terms of net designed heat release in heat units per timed period (i.e., British Thermal Units per hour, mega joules per hour, kilocalories per hour).
“The unit shall be supplied with a lockable operations store, that shall be initially supplied with the following consumables:
• A first aid kit, suitable for addressing the hazards presented by the unit.
• 5 full sets of personal protective clothing and equipment.
• Operating logbooks.
• Unit cleaning equipment.
• Unit routine maintenance equipment and associated spare parts.
• Lubricants as appropriate.
• 3 Fire extinguishers.
• Any other consumables considered necessary by the Supplier.

 

2021-02-23

Large Incinerator Model TS800 Top Openning Door 800kgs/500kgs/300kgs/200kgs/100kgs per hour


Items/Model

TS800

(Optional Part:

Stainless Steel Wet scrubber & PLC Control System)

Picture

 

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 100kgs per hour(Optional 800kgs/500kgs/300kgs/200kgs)

Feed Capacity

Average 3000kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

3000Liter

Internal Dimensions

300*100*100 cm

Secondary Chamber

800Liter

Feed Mode

Manual/Forklift

Voltage

220V/380V

Power

5.0Kw

Oil Consumption (kg/hour)

Average 20.4(DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

800Liter

Feed Door

200x100cm(Electric Opening)

Chimney

6Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

9000kg

External Dimensions

600x220x320cm(without chimney)


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Optional Part:

Stainless Steel Wet scrubber & PLC Control System 


HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2020-11-04

Top Feeding Door HICLOVER 10-500kgs/Hr.Double Combustion Chambers Waste Incinerators

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.

 

Our products ensure efficient, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies , Drug Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Feed Door

80x60cm

80x60cm

 

 

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


Type of waste: medical and industrial (solid and semi solid hazardous)
Type of waste : Bio-medical & Hazardous (Solid and Semi Solid) 
If you are a hospital then Please also tell how many bedded hospital : No aren’t a hospital 
Quantity of waste generated per day in kg : 6000 kg
Duration C incinerator will be used per day :1 C 16 hours 
Approximate moisture content: 47 to 53%
Availability of power and type : 3 Phase, 440 Volts
Details of space available : Min. 10000 Sq.  ft.
Do you require an automatic loading system? Depends if it is a continuous burning or interval burning.
How soon do you require the system to be delivered? 8 weeks
Whether the location is a coastal area : No
An other specific requirements: Automatic PLC Control System.
Burning Rate: 500kg/hour
Volumetric capacity Primary Chamber: 500kg
Burner Type: Diesel Operated
Burning Process: Continuous

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-16

Clover's Social Media