Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

hospital for burning hazardous waste and chimicals

use in the hospital for burning hazardous waste and chimicals, minimum Capacity 300 per hour. I will be reselling to my client?. Below is the information I was given and nothing else. The hospital incinerator for use in the clinical waste as required by international environmental management. Minimum 300 Kg capacity/hr, Fuel fired, refractory lined, chimney and sampling prot. Minimum temperature of 1100 degree Celsiu.the incinerator machine for burn 500kg per hour. project about burn medical waste of the hospitals.Just want to price of you various types of Medical Rubbish Incinerators.need all information on 300 kg per hour unit.  availability.  operational costs using diesel (other).the waste is Human Tissues. And we have 10 kg per day; we need incinerator for medical waste.Burn Capacity: 50kgs per hour (Average capacity according to Medical Waste).please forward information about pricing on all of you pet crematory models.Regarding Gas Incinerator, Please note that Fuel for the Incinerator
will be Gas. As gas is chip in our country.

burning hazardous waste and chimicals incinerators

3 types of incinerators, which are 10Kgs, 20Kgs and 30Kgs for our Tawfiq Hospital use in Malindi, Kenya. we are an

environmental consulting firm as I’ve mentioned previously, we have already contracted with a French company specialized in

the sale of solid waste incinerators (ATI) and we bought a crematorium for the disposal of solid waste, including $ 180

thousand dollars, and now we want to get into the business of selling waste incinerators animal, and since it does not have an

agent in Saudi Arabia.  The three models you have indicated are based on 24 hour operation. Could you please make suitable

recommendations for 8-10 hour shift each day (including cooling time)? I assume we will need bigger capacity incinerators for

each of the three requirements.I am interested to know more detailed specifications and prices for your SYC-20 incinerator. I

am in the market for a small and easy-to-operate incinerator, however have little to no experience with such items.

installation and construction of SOLID WASTE
MANAGEMENT COMPLEX , for that purpose we need Sixteen (16) ton/day (7,538 kg/day) Capacity Incinerator System.1.5 ton garbage

per day,

required number of units -10 to 25 numbers

Installing different type of waste Management systems preferably Incineration and others for the state Jammu & Kashmir India

manufacturer and exporter of various Incinerator and other products.

Please be noted that we are a leading Bangladeshi business house dealing in various Medical, Surgical, Dental, Hospital

products, Plant and Machinery and so on

Most important is transformer, 220v motor, Temperature thermocouple, Blower of Primary Burner.

base on this portable incinerator,
1. the type of waste it can be use for (treatment).Hospital waste incinerators with reduced or carbon dioxide  CIF khartom –

Sudan

medical waste incinerators models for hospitals of 100-300 bed and 100-1000bed,kindly send price quote of all the YD models

and mode of transaction /delivery to nigeria

incinerator is for use in the hospital for burning hazardous waste and chimicals, minimum Capacity 300 per hour.

The hospital incinerator for use in the clinical waste as required by international environmental management. Minimum 300 Kg

capacity/hr, Fuel fired, refractory lined, chimney and sampling prot. Minimum temperature of 1100 degree Celsius kindly quote

me best price for resale.The best price for resale for the between $7000 to $12000 Usd I already have quotations just need the

best price please. price should be CIF Johannesburg or Durban

Hot Sale Small Scale Waste Incinerators 30 and 50 kgs per hour capacity

incinerators at three facilities to process healthcare waste

a. 2.5 metric tons per day healthcare waste incinerator

b. 1.5 metric tons per day healthcare waste incinerator

c. 300 kg per day healthcare waste incinerator

Our preferred technology is double-chamber incineration, but if you recommend an alternative technology, that is acceptable as well.

We request information on the following for each of the above requirements:

1. Capital cost (delivered cost in Oman)

2. Operation and maintenance costs (per year)

3. Number of operators required

4. Product specifications (sizes, temperatures, residence time, cycle time etc)

5. Other auxiliary equipment that is required or recommended by you

medical waste PYROLYTIC INCINERATOR

TECHNICAL SPECIFICATIONS: PYROLYTIC INCINERATOR

Parameter Compliance
Type of Waste To treat medical waste, categories A,B,C,D,E
Type of Incinerator Pyrolytic
Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg
Loading Manual, Batch Load
De Ashing Automatic or Manual batch de ashing
The incinerator must avoid the release of black smoke and fine dust during the loading
Primary chamber capacity 2-3 m³
The insulation   of the combustion chamber should be composed   of refractory bricks, having a higher content of aluminium and insulates,
The plate of combustion in carborundum avoiding the fixing of glass and slags
Hours of operation /Day >10 hrs
Max Operating Temperatures 1400 °C
Normal Operating Temperatures(Primary) >850 °C
Operating Temperature(Secondary) >1100 °C
It should have digital temperatures regulator( Temperatures regulator in digital watch)
Carbon content of ashes <2%
The installation should be completely free from visible smoke as well as offensive odours
Residence time in second chamber 2 second minimum
The internal diameter of the Chimney :Ø 400
Height of stack >8m
Burner operation Automatic On/Off
Fuel Diesel
Fuel consumption at raed capacity >7kg waste /ltr
Electricity consumption <2kW at rated capacity
Operating Voltage 220 – 240V AC 50Hz
Spare parts Supply for 1 year quoted as option
Consumables Supply for 1 year of operation to be mentioned as option
Warranty Parts and service support: 1 year minimum post comissioning
Service support <72 hours
Emission standard Compliance BS3316 or equivqlent standard
Process filtering system Scruber to be mentioned as option
CE Manufacturing Compliance BS EN 746-2-1997
Design Specification Type A,B,C,D,and E of medical waste
Installation and Comissioning Included in condition of supply
Training in preventive and curative maintenance and use of the incinerator Operator training inclusive in offer
Capacity to treat Plastic Not less than 40% by weight

 

Clover's Social Media