Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
BIO WASTE INCINERATOR
50 kg/ hour capacity incinerators
· Burning Rate: 50kos/hr
· Feed Capacity: 150kqs
· Primary Combustion Chamber: 900 liters
· Secondary Combustion Chamber: 300 liters
· Mix Combustion Chamber: Yes
· Smoke Filter Chamber: Yes
· Feed Mode: Manual
· Power: 0.7Kw
· Fuel Type: Diesel Oil/ Natural Gas/LPG
· Internal Dimensions: 120 x 90 x 85cm (primary chamber)
· External Dimensions: 200 x 160 x 310cm (without chimney)
· Burning Efficiency: >98%
small scale medical waste incinerators.The required burning capacity of those incinerators are 10 kg and 15 kg/hr .The fuel oil using for those incinerator is diesel oil .
small scale incinerator of burning capacity
Poultry Incinerator – 400 kgs feed per day.a small scale incinerator of burning capacity 30kg/hr=1No. Note that it should be portable as this is meant for oil fields work on tented camps. Also it has to be diesel operated as our location is remote. 150!kg per hour LPG smokeless incinerator to be used at the international airport. This is a requirement bu the bio security that all international flights need all rubbish burnt within a set time.Required load capacity is 150Kg
Chamber – Primar 900 liters Secondary: 300Litres
Chimney 8M
Burning Rate: 50kgs/hr Yes
Feed Capacity: 150kgs Yes
Primary Combustion Chamber: 900 litres Yes
Secondary Combustion Chamber: 300 litres Yes
Mix Combustion Chamber: Yes Yes
Smoke Filter Chamber: Yes Yes
Feed Mode: Manual Yes
Power: 0.7Kw Yes
Fuel Type: Diesel Oil/ Natural Gas/LPG Yes. Different Price if oil or gas fuel.
Internal Dimensions: 120 x 90 x 85cm (primary chamber) Yes
External Dimensions: 200 x 160 x 310cm (without chimney) Yes
Burning Efficiency: >98% Yes
ecologically friendly incinerator
50 bed hospital and would like to have your recommendation for incinerator that can effectively handle the load of 50 bed hospital.Incinerator for burnable garbage (paper & organic) medium capacity (100/150 lts). Bio Medical Waste Incinerators,
Capacity: 50kgs per hour Medical Waste Incinerator Model TS50 ( PLC ) with both option on Fuel ( Natural Gas and / or Diesel2 Burners
2 Temperature Thermocouple
5 meters for thermal gasket
1 incinerator control case
1 Blower ecologically friendly incinerator for burning polyproplylene bags we have 10 tons weekly
500kg/day burn capacity incinerator
in acinerator with 300 kg/ hour by double filter wet and dry.Pet Dead Body Incinerator upto 80 kg ,gas operated is prefered. animal waste incinerator with capacity about 40Kgs. We will use this product to burn the animal corpses in normal way (not sick aninal).Could you please forward me quotation for incinerator that is suitable for service Town with a population of 200,000 people including other general town waste to burn. Technical specifications data sheet
List and quantities of consumables required per month
List and cost of all the spares required annually
List and costs of all the spares required in 5 yrs
List and costs of all the spares required in 10 yrs
2 incinerators one with 500kg/day burn capacity another one with 1000kg/day burn capacity
1 x Electrode
1 x Fuel Filter
1 x Photocell
1 x Flexible pipe
1 x Nozzle
1 x Control Box
WASTE INCINERATOR
– 150 KG/HR
– Compliant with EU rules, Directive 2000/76/EC
– Fuel type: Diesel
– Easy management and maintenance
– Temperatures:
850 deg C for municipal waste
1000 deg C for medical waste
1100 deg C for dangerous waste containing halogenated organic substances with content of chlorine or its compounds.