Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Hospital Waste Management

Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description        Minimum Requirements
Design standard    Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney    Top mounted, self supporting
Incinerator performance    150kg/hr
Refuse     Hospital waste and carcasses
Recommended Temperatures    Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners    At least 3000mm
Loading door opening    Minimum 700mm x 600mm
Hearth area    5.00square meters
Description or grate/hearth    A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume    At least 3 cubic meters
Mixing chamber volume    At least 1 cubic meters
Settling chamber volume    At least 3 cubic meters
Weight excluding chimney    15, 000kg at manufacture
Firing tools supplied    Hoe, Poker and rakeMaterial of construction    Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable  general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory  concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation  to walls     1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base    3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught

Air supply

Electric

Barometric indicator, door operated draught limiter

Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required    415 Volts Three phase.
Auxiliary  fuel    Electrically operated only
Emission     Multiple chamber design with inbuilt emission control
Paint: Case and stack    400⁰C Heat Resistant Grey
Temperature of case    100⁰C

Incinerator for hospital waste management

Incinerator for hospital waste management with the following features:

• In high temperatures (pyrolytic incinerator two chambers with temperatures ranging from 950 º C to 1320 º C;

• Ability to destruction of 400 to 600kg per hour;

• Capable of destroying microorganisms;

• Drain ash;

• Drain needle and glass crusher;

• Porch with tap water for hand washing and decontamination;

• Observe the issue of environmental quality standards, emissions fluent and regulation on the issue of waste;install large incinerator to one of the biggest veterinary hospital in KSA so if you will support us with one unit (large incinerator) and environmental with onsite training , the capacity for the unit is 2000 Kg for cattle , horses and farm animals also suitable to all animal waste types , we need it diesel fired . OES-Industrial MultiWaste Incinerator System (Solid/Liquid)

Scope of the Work:
Design, installation and commissioning of multi industrial waste incinerator.
Capacity: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with dual chamber system)
1st chamber-870 Deg.C – 900 Deg.C
2nd chamber-1000 deg.C – 1200 Deg.C

Sources Of The Wastes
The following types of wastes can be treated by using incinerator.
a). bio medical waste/pharmaceutical waste
b). solid chemical waste/textile industries waste
c). liquid chemical waste
d). dyes and intermediate waste
e). organic chemical waste
f). liquid ink waste/acidic residue
g). insecticides/herbicides/pesticides
h). fungicide waste
i). ethanolamine
j). amino ethanol
k). mono ethanolamine
l). ETA,MEA waste
m). wastes after treatment of chemicals in etp plant.
n). mixed liquor waste water
o). alcoholic waste.
p). agricultural liquid chemical waste.
q). sludge mix liquid
r). slurry/adhesive/grease/powder coating wastes.
s). semi solid liquid chemical waste
t). bulk dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass beads
w). used tires.
x). used cotton rags
y). contaminated plastics/resin wastes.
Scope of Work:
Incinerate all types of liquid/solid hazardous/chemical/non hazardous wastes avaliable in the industries with proper scrubbing system with standard emission rates.
The dual stage incinerator helps to burn the waste in two stages , first at a medium temperature of 870- 900 Deg C and the second stage at 1200 deg C
Producing ash and Gaseous fumes which are treated with cyclone type wet scrubber and caustic scrubber to produce air with pollutants in the permitted range and Non hazardous ash mainly inorganic salts.

Incinerator utilities
Incinerator should have following criteria:
Metallic seal structure with ceramic insulation to avoid heat  radiation and control radiant temperature
Advanced gas treatment system to avoid emission of toxic gases (scrubbing system).
Low consumption high efficiency compact automatic burning system.
Low running and maintenance costs
Fully automatic and simple to operate control panel
Afterburner Preheat
Dense refractory concrete lining rated at 1600 C
Solid Hearth to allow maximum Burnout
Large Top opening lid for easy loading
Wide door for ash removal
Optional Stainless Steel Casing
Heat recovery option

INCINERATOR DIESEL DRIVEN

INCINERATOR, DIESEL DRIVEN
waste type : HEALTH CARE WASTE
Waste calorific value : 4000KCAL/KG
Moisture Content : 10-25%
Nominal Capacity : 50Kg/Hour batch load
Secondary Chamber : 2 Seconds @ 850degrees C
The primary combustion chamber must ensure minimum exit temperature is not less than 850 degrees C.

INSULATION
Calcium Silicate
Limiting Continuous service limit 1000 degrees C.
Thickness 25mm

THROUGHPUT
50kg/hour at a nominal calorific value of 4,000 kcal/kg and an average bulk density of 120kg/MCubed for general waste and 160kg/MCubed for health care waste.

INCINERATOR For incineration of Laboratory wastes materials

Incinerators to be suitable for the professional disposal of clinical & medical waste / garbage with a higher load capacity in the range of approximately
1000-1500 Kg.  The durable, self-contained incinerators shall offer an effective and highly efficient, safe disposal and to be manufactured according to applicable international directives, e.g. CE, EU, etc.
Type of Fuel: Diesel or Petrol or Natural Gas. Temperature controlled,
efficient burner for optimum fuel economy. incinerator in the best technology and an approximate capacity of 2000 ton / year. Possibly an incineration capacity of 200 kg / hr and a calorific value of 7500 kcal / kg. Industrial and domestical waste.INCINERATOR For incineration of Laboratory wastes materials

Features
i.Smoke and smell free
ii.High Temperature , refractory lining with excellent heat retention
iii.Quick heat up time
iv.Must have a secondary chamber
v.Constant run fan
vi.Temperature monitoring
vii.Thermostat Control

Technical Specifications
i.Capacity :                    approx. 0.20 m3
ii.Fuel consumption:        5 litres /hour Diesel Oil
iii.Min Operating Temp:   900 oC
iv.Max Operating Temp:   1350 oC
v.Residence Time:           2 sec
vi.Burning rate:                 35kg/hr minimum

Accessories
Standard accessories required

Consumables and Spares
Supplied with  spares and consumables to carry out at least 1000 tests

MEDICAL BIOLOGICAL WASTE INCINERATOR

It should  be  a three chambered incinerator
The load capacity of 250 kg
The housing for the incinerator should be able to withstand the temperatures and other operational requirements.
The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc.
It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan.
The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion.
In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere.
A system for continuous emission Monitoring and Environmental Monitoring.
A mechanism with which to treat the waste water before discharge into the sewerage system.
Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation.
Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney).
High power electricity and emergency generator connection for automated ignition purposes.
The chimney should be tall enough and be at least one meter above the tallest building in the vicinity.
The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250.
Other Requirements
Training of all the personnel involved in health care waste (HCW) management.
The Automatic Feeding system of the Incinerator
Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber.
An Automatic bottom ashes discharge system.

Clover's Social Media