Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
double chamber incinerator
Waste calorific value : 4000KCAL/KG
Moisture Content : 10-25%
Nominal Capacity : 50Kg/Hour batch load
Secondary Chamber : 2 Seconds @ 850degrees C
The primary combustion chamber must ensure minimum exit temperature is not less than 850 degrees C.
INSULATION
Calcium Silicate
Limiting Continuous service limit 1000 degrees C.
Thickness 25mm
THROUGHPUT
50kg/hour at a nominal calorific value of 4,000 kcal/kg and an average bulk density of 120kg/MCubed for general waste and 160kg/MCubed for health care waste.All types of chemicals substances (Biocides) that utilized for Oil operation sites (water base Drilling, oil operating facilities for the corrosion and others: The examples of the biocides are “WS-36, HAI-85M, SODA ASH, DSMA, MICRO MATRIX, CALCIUM CARBONATE FINE, BARAKLEAN, GILSONITE, MIXED WASTE SOIL CHEMICALS, ZINC CARBONATE, CAUSTIC SODA, ENVIROTHIN, BARAZAN D,..etc) as well as the substances are liquid and solid.
2. In regards to the quantity of burning the waste, it could be 200 – 500 kg per hour.
3. Our Operational time can be in Day and can be at night.
4. Can you please give me the cost of unit operated with Diesel and Gas.The primary combustion chamber is the main structure of the incinerator, fabricated from mild steel plate and stiffened with rolled steel sections. It is carried from the floor level on a substantial steel support frame. Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or high strength castable.
The primary combustion chamber must ensure minimum exit temperature is not less than 850°C.
One Manual Load Incinerator comprising:
·???????? Manual Loading door
·???????? Horizontal solid hearth, refractory lined primary combustion chamber. Approximate dimensions 800 mm diameters x 2100mm long
·???????? Full sized bulk load/ash removal door
·???????? 1 off diesel-fired ignition burner — temperature controlled
·???????? 1 off combustion air supply fan and distribution system, automatic control
·???????? High capacity secondary combustion chamber with residence time not less than 2 seconds @ >850°C
·???????? 1 off diesel-fired afterburner — temperature controlled
·???????? Control panel — automatic operation
e????? Temperature indication primary and secondary chambers 0-1200°C
e????? Refractory lined flanged chimney to a height of 10M above ground level
SOLID WASTE INCINERATOR
Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal.
Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating. bio medical waste treatment plant ( Incineration )with panel.
SOLID WASTE INCINERATOR Feeding Capacity: 200 to 220 Kg.
Burn Rate * 60 Kg / hr
Ingredients to be burned Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc.
Chambers * Dual Chamber.
1: Primary Controlled Air
2: Secondary Excess Air
Temperature Monitoring Required
Temperature Control to Primary & Secondary Chambers Required
System Status & Alarms Required for all necessary parameters.
Fittings & Accessories Complete Package is required ( Including Nozzles & Flanges etc.)
Installation Requirements. As low as possible . Almost Plug & Play type.
Dimensional Sketch, Operation & Installation Manuals. Required
Off – Gas System Required
Heat Insulation Required for indoor installation
Delivery Karachi Sea Port – Pakistan
The details of Components of incinerator is as follows:
Component Name Features Range.
Primary Chamber Temperature Required* 800 – 1000 deg C.
Heating Source Natural Gas
Secondary Chamber Temperature * 1100 – 1300 deg. C
Heating Source Natural Gas + Propane or Fuel Oil as an additional source
Off – Gas Residence Time 2 Seconds.
Refractory Material Material * Alumina ( 56 – 80 % Pure )
Lining * SS 316L
Life Span * 10 – 15 years.
Rating Temperature 1600 – 1800 deg. C
Media Slightly acidic
Insulation Material Ceramic Fiber
Thickness 25 “ minimum
Feeding & Ash Removing System Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Spares Required for 5 Years trouble free operation
CONTAINERIZED INCINERATOR FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES
CONTAINERIZED INCINERATOR FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES (BOTH DOMESTIC AND INDUSTRIAL) AT A MINIMUM RATE OF 300KG/HR WITH THE FOLLOWING SPECIFICATIONS:
Ø PRIMARY CHAMBER VOLUME 7.2M³
Ø BURNING CAPACITY 300Kgs/hr.
Ø PRIMARY CHAMBER TEMPERATURE 850⁰C AND SECONDARY CHAMBER TEMPERATURE 1100⁰C
Ø REFRACTORY THICKNESS 225MM; REFRACTORY WITHSTAND TEMPERATURE 1400⁰C
Ø RAM LOADER CAPACITY 0.75M³; OPERATIONAL CYCLES PER DAY 8-16 Hrs.
Ø FUEL DIESEL/NATURAL GAS; NUMBER OF PRIMARY BURNERS & RATING: 2 @ 250kw
Ø NUMBER OF SECONDARY BURNERS & RATING: 2 @ 400kw; ELECTRICAL SUPPLY 230V 60Hz
Ø BIN TIPPER, MONITORING SYSTEM, CLEANING SYSTEM
Ø GAS CLEANING AND GAS MONITORING.MSW1000 General Medical Waste Incinerators burn rate up to 100kg/hr
A2400 Animal / poultry Waste Incinerators burn rate up to 200kg/hr.Laboratory waste Management system
01. Liqued water purification system.
02. Number of laboratories – 05
03. The estimated liquid water waste – 6000 L including
a. chemicals
b. toxins
c. Bio Hazardous materials.
Temporary allocated space for purifications system- 30×20
The following should be indicating in the biding document
1.Method of disposing treated waste water
2.Method of discarding the sludge
3.To follow ISO standard/regulations of Central Environment Authority[CEA]
4.Time frame for construction
5.Request the cost for each item of the project [Consultancy/designing/construction] as well for the whole project.
6.Warranty period and maintaincne.
dispose Medical waste IV
the incinerator can be used to dispose Medical waste IV, used needles, used syringes, scalpels, used dressing material ,personal protective equipments like gown, gloves etc. amputated body parts, excreta from patients and other laboratory waste.incineration units that can handle a mix of medical and hazardous wastes. The medical wastes include (but are not limited to) materials contaminated with blood, bodily fluids, fecal matter, and human tissue/organs from surgery. The hazardous compounds include (but are not limited to): xylene, toluene, chloroform, methylene chloride, trichloroethylene, acetonitrile, formaldehyde wastes, chemotherapy wastes (e.g., Chlorambucil, Cytoxin, Daunomycin, etc.) radiology wastes (e.g., glutaraldehyde), and mercury-containing compounds.includes amputated body parts, body fluids including contaminated blood, blood products, excreta from patients, cultures of contagious viruses and other laboratory wastes e.t.c.
Medical might also include used needles, used syringes, used , expired or contaminated dressing materials like bandages, plasters and plastics, e.t.c. The Incinerators should also allow for disposal of other wastes generated in hospital environment.Technical Specifications for Portable Incinerators
The Chamber volume of approximately 0.37m3 and a
1 combustible load volume (volume of material) of
approximately 0.30 m3
2 Burner power of approximately 189,000kcal/hour
Maximum Combustion Temperature of up to 1250
Degree Celsius
Type of emitted Gas: Inert and nil environmental pollution effect
Electrical Power: 220V/50 or 60 Hertz
Fuel: Diesel
Electrical consumption of approximately: 0.35 kw/hr
Fuel consumption range: 7 – 11 ltrs/hr
Controls: Incinerator control including control panel, timer, display for monitoring combustion temperature, system error display, etc.
Packaging/Installation: Incinerator fully assembled and ready to be plugged in power source
Instruction manual: Package must be provided with instruction manual including detailed information to installation, operation, maintenance, interpretation of trouble shooting signals and contact telephones
numbers/emails of local or overseas manufacturer’s technicians that can be contacted for guidance on operation of the equipment, if necessary.
training guide/manual on a compact disc including a demonstration for installation, operation and
maintenance, as well as safety guidelines, etc.
Scope of Supply: Package must be provided including
all the required accessories for installation and must
include spare parts/consumables that are required for a
one year period at a combustion rate of up to 8 hours
daily
Warranty must be provided for a 5-years period
starting with the incinerator’s installation and
including the provision of accessories and
consumables
WASTE CATALOGUE AND HAZARDOUS WASTE LIST
1 Incinerator 30 =KG burn/h and it must have a Scrubber.
2 Incinerator must have Electrical Plastic Shredder for cutting of glass bottle,surange of Medicine.
3 Incinerator must have Electrical Auto Clave or Microwave for Dis Infection separately with incinerator.
4 Incinerator must have Double Chambers first Chamber must gave 800C temperature and secondary Chamber working 1200C temperature.
5 Incinerator in out place must have a Parameter to show inner temperature of incinerator.
6 Incinerator must work in two systems Electric and fuel describe in which kind of fuel works.
Note we want it works on diesel fuel and electric also.for a small pig slaughterhouse project in Vietnam we are looking for a
solution to destroy safely inedible and seized animal products.
As the slaughtered pigs are consumed by more than 90% (from hooves to
head, blood, etc) the waste volume is quite small even in
slaughter-points with up to 100 slaughtered pigs per day.
Although the use of meat and bone meal is not prohibited in Vietnam the
small volumes of waste do not seem to justify the installation of a
rendering unit, not even of a batch cooker, so incineration seems to be
the best option.
I would like to receive more technical details e.g. fuel consumption for
incinerating 100/200 kg of animal products per day and also the FOB
price of the unit.The types of waste to be treated are (after EUROPEAN WASTE CATALOGUE AND HAZARDOUS WASTE LIST, 2002):
18 01 01 sharps (except 18 01 03)
18 01 02 body parts and organs including blood bags and blood preserves (except 18 01 03)
18 01 03* wastes whose collection and disposal is subject to special requirements in order to prevent infection
18 01 04 wastes whose collection and disposal is not subject to special requirements in order to prevent infection (for example dressings, plaster casts, linen, disposable clothing, diapers)
18 01 06* chemicals consisting of or containing dangerous substances
18 01 07 chemicals other than those mentioned in 18 01 06
18 01 08* cytotoxic and cytostatic medicines
18 01 09 medicines other than those mentioned in 18 01 08
18 01 10* amalgam waste from dental care