Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
medical waste incinerator
medical waste incinerator: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
Especifica??es Gerais 6 mm plate steel sheel construction
11cm 1400°C refractory Liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000°C
400°C silicone Based finish paint
alloy temperature sensor
factory wired and tested
Capacity 20kg/hr
primary Chamber 1607 L
Hearth area 1.36 aq.m
Secondary Chamber 694L
Primary burner (oil) 420.00btu
Secondary burner (oil) 900,000btu
Secondary combustion 1/6 hp
Exhaust stack 46cm x 6m
Electrical service 220/50
System weight 5,700kg
Dimension “D” 152cm
Doad port height e 60x60cm
Ash port height e 36x36cm
General Specifications 6mm plate steel sheel construction
11cm 1400 ° C refractory liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000 ° C
400 ° C silicone based paint finish
alloy temperature sensor
factory wired and tested
Capacity 20kg/hr
primary Chamber 1607 L
Hearth area 1:36 aq.m
Secondary Chamber 694L
Primary burner (oil) 420.00btu
Secondary burner (oil) 900,000 btu
Secondary combustion 1/6 hp
Exhaust stack 46cm x 6m
Electrical service 220/50
System weight 5.700 kg
Dimension “D” 152cm
Doad port height and 60x60cm
Ash port height and 36x36cm
medical, hospital, veterinary and industrial wastes by medical waste incinerator Process.
So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus.
medical waste diesel incinerator
medical waste diesel incinerator Burning Rate:47.5–50kg/hour
Minimum Operating Temperature:850o C(primary combustion)
Maximum Operating Temperature:1450 oC(Afterburner chamber)
Secondary Burning Capacity:Compulsory
Density Insulation:20mm High
Refractory Casting:Minimum 65mm
Heavy duty refracting lining to withstand:1500 oC
Average burn out time :maximum:3 hrs
Fuel type:Diesel
Fuel Consumption in L/hr:7.5 to 9
Residence time in secondary chamber:2sec
Residue ash post 100kg:Max 3.8kg
Device for preventing infectious spatter and/or cross-contamination by safely sterilizing needles, rings, etc. by infrared heat.
Electrical characteristics
1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 type.
2) Protections against over-voltage and over-current line conditions.
3) Compliance with applicable Haitian standards and regulations.
Operational characteristics
4) Fast complete sterilization in around 5-7 s.
5) Fully isolated quartz/ceramic tube, to grant safety for the user (no open flame).
6) Working temperature around 820°C.
7) Mounted on a stable base, as per example below.
waste incinerator manufacturers from china
Incinerate: medical waste and general waste Capacity to burn waste:
400-500kg/hr
Fuel: Diesel
Fuel Consumption: 10 liters/hr maximum
Incineration temperature: 950-1300 degrees centigrade
Casing: thick (min 5mm) stainless steel casing and fully insulated to
withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz
high-capacity, powerful, European Standard incinerator,ideal for high volume incineration,with integral after-burner for greater efficiency and emissions control.
Waste Type and Burn Rate
Designed specifically for use by poultry farmers,
sheep farm owners, abbatoirs and for pet
cremation. The incinerator will burn up to 50kg of
waste per hour (up to 150kg burn
Construction
Mild steel welded fabrication consisting of sheet steel
and structural section supports.
Lining
Monolithic high grade refractory concrete with high grade insulation backing.
Burners
Fully automatic, high-efficiency burners with electronic ignition, flame recognition and combustion control devices fitted.
Loading – Ash removal
Manual ash removal from the primary chamber. (Ash doors are available on request).
Exterior finish
Multi-coat high quality, high-temperature aluminium enamel top coat paint, finished in silver.
Control
Fully automatic sequential control provided by internal
waste incinerator manufacturers from china, PLC system providing control of:
1. Secondary chamber pre-heat
2. Burn cycle (variable)
3. Cool down cycle
Fuel Options
Diesel, LPG, Natural or Bio Gas.
Typical Fuel Consumption
Diesel: 8 / 10 litres per hour
Liquid Propane Gas: 6 / 8 litres per hour
Natural Gas: 7 / 9 Nm3 per hour
Electrical supply
240volt 16 amp.
Key Specifications
Chamber Volume 2.38m3:
2.2m (l) x 0.9m(w) x 1.2m(h)
Load Capacity up to 1000kg
Load Method Top.· Type: Pyrolytic
· Use: For drugs
· With Chassis to be Mounted in truck/lorry
· May have a primary and secondary combustion chamber
· Must have a dilution chamber
· Capacity: 100 Kgs per hour
· Power Source: Diesel or Natural Gas or Liquified Natural Gas
incinerator for medical waste
MINIMUM REQUIREMENTS FOR ENGINE OF INCINERATION
CAPACITY OF INCINERATION 30KG / H
1. GENERAL SPECIFICATIONS:
The incinerator for medical waste must be designated for the destruction of all types of waste produced by the Center for Health (waste type hospital, clinic, medical laboratory for destructive capacity of 30kg / h) .
Pyrolytic gasification combustion control shall:
? Prevent development of black smoke and dust formation tine loading of waste;
? Provide regular and complete combustion of the waste;
? Provide controlled guaranteeing the absence of color, cloud of smoke or burning odor;
? Allow limited fuel consumption
The incinerator with pyrolytic combustion must have:
a. Combustor:
– Chamber strong steel support legs sheet;
– The lining is made of refractory bricks and a thermal insulation ensuring a minimum temperature of the sheet;
– The sole combustion is composed of a refractory lining specially designed to meet the thermal, mechanical and corrosive liquid waste requirements and molten glass;
– The dimensions of the floor are equipped laterally primary air nozzles that fuel combustion;
– The hearth is equipped with a stirring system of waste combustion is controlled switch;
– The recovery operation of the ashes will take place once a day line before starting the day’s operation.
Composition of the refractory lining:
* Insulation:
– Operating temperature: 1000 ° C max
– Nature: Calcium Silicate
– Thickness: 80 mm
* Refractory:
– Operating temperature: 1650 ° C max
– Nature: Refractory bricks with 42 alumina
– Thickness: 110mm
Burner combustion:
– The combustion chamber is equipped with a burner to line to ensure correct temperature for the total destruction of waste combustion;
– Automatic monobloc burner and flame plunge equipped with an electronic ignition system and permanent ventilation.
Air fan:
– A primary air and secondary air fan provides the necessary oxygen delivery
– There is a motor operated valve that controls the flow according to the combustion.
– The pressure of the fan is 500 mm CE to pierce the mass of waste during combustion.
b. Post – combustion chamber:
– Treat the gas has a minimum temperature of 1100 ° C with a minimum residence time of two seconds the afterburner is to;
– A secondary air injection is expected and provides perfect oxygen content;
– The burner ensures a minimum temperature of 1100 ° C continuous;
– The design of this burner is similar to combustion burners;
– The afterburner is equipped with access doors in order to ensure regular cleaning of dust;
– The afterburner is lined with high thermal insulation with a thickness of 150 mm
c. Cabinet, control and regulation:
– The entire installation will conform to European standards (EU)
– The electrical power is 220V 50Hz single phase.
– Regulators of temperature with digital display:
? 1 to regulate the temperature of the combustion chamber
? 1 for controlling the temperature of the afterburner
? The manual controls are provided on each item.
2. PRODUCT DIMENSIONS
Description Dimensions
Destructive capacity 30 Kg / hour
Operation 12h/24, 6d / 7
Fuel diesel oil
Chimney Height: 5m, Diameter: 280mm
Volume of combustion
chamber Combustion: 0.3 m3
Post combustion: 0.2m3
Mixed combustion chamber: 0.3m3
` TEMPERATURES:
. Combustion
. Afterburner
900 ° C
1100 ° C
POWER BURNER
Combustion
Afterburner
0.11 KW
0.11 KW0
Fan power 0.37 kW
small scale medical waste incinerator
Toxic and dangerous wastes,
Medical pharmaceutical and hospitable liquids Wastes
Domestic garbage
Electric and electronic wastes
Industrial wastes
In General, all type of wastes and garbages
Capacity 50-60Kg/h
Combustion supporting materials
Coal oil, diesel oil
Temperature inside
800-10000C
1000-12000C
Burning efficiency
>98%
Power consumption
1.3KW
Noise
<78dB
Index of let smoke and waste gas
Ringelman’s smoke index< level 1
Smoke concentration
Oil
45.5
(mg/m3)
Gas
25.5
(mg/m3)
SO
Oil
0.176
Gas
0.065
NOX
Oil
0.031
Gas
0.038
H2S
Oil
0.016
Gas
0.008
CO
Oil
8.32
Gas
35.64
small scale medical waste incinerator Requirements
Incombustible and explosive materials not allowed in
Process manner
Two combustion cabinets (wetness drying, high temperature dust removal)
Combustion / Burner
Good Quality made in Italy
Blower
Good Quality made in China
Control Electrical
Good Quality made in China
Capacity 50 Kg/h
Working Voltage
220 V
Power
1000 W
Applied For
200 beds
Input Fashion
Manual
Medical Incinerator, 24 kg/hr
Medical Incinerator, 24 kg/hr including panel board, controls and accessories
Furnace gate
Chimney
Blower
Combustion burner
Medical Incinerator, 12 kg/hr
Medical Incinerator, 12 kg/hr including panel board, controls and accessories
Furnace gate
Chimney
Blower
Combustion burner
Medical Incinerator, 6 kg/hr
Medical Incinerator, 6 kg/hr including panel board, controls and accessories
Furnace gate
Chimney
Blower
Combustion burner